Modellnummer
|
|
GT3-36KL1
|
GT3-40KL1
|
GT3-50KL11
|
GT3-60KL12
|
GT3-36KL11
|
GT3-40KL11
|
GT3-50KL1
|
GT3-60KL11
|
GT3-75KL11
|
GT3-60KL1
|
GT3-75KL1
|
|
|
|
|
Max. DC-Leistung
|
|
54 kW
|
60 kW
|
75 kW
|
90 kW
|
54 kW
|
60 kW
|
75 kW
|
90 kW
|
112,5 kW
|
90 kW
|
112,5 kW
|
|
|
Max. Eingangsspannung
|
|
800 V
|
800 V
|
800 V
|
800 V
|
800 V
|
800 V
|
800 V
|
800 V
|
800 V
|
800 V
|
800 V
|
|
|
Nominal Eingangsspannung
|
|
370 V
|
370 V
|
370 V
|
370 V
|
370 V
|
370 V
|
370 V
|
370 V
|
370 V
|
370 V
|
370 V
|
|
|
Min. Eingangsspannung
|
|
200 V
|
200 V
|
200 V
|
200 V
|
200 V
|
200 V
|
200 V
|
200 V
|
200 V
|
200 V
|
200 V
|
|
|
Max. Einggangsstrom
|
|
160 A
|
160 A
|
160 A
|
160 A
|
240 A
|
240 A
|
240 A
|
240 A
|
240 A
|
320 A
|
320 A
|
|
|
MPP(T) Spannungsbereich
|
|
180~700 V
|
180~700 V
|
180~700 V
|
180~700 V
|
180~700 V
|
180~700 V
|
180~700 V
|
180~700 V
|
180~700 V
|
180~700 V
|
180~700 V
|
|
|
Anzahl MPP Tracker
|
|
|
DC Eingänge
|
|
8
|
8
|
8
|
8
|
12
|
12
|
12
|
12
|
12
|
16
|
16
|
|
|
|
|
Nominal AC-Leistung
|
|
36 kW
|
40 kW
|
50 kW
|
60 kW
|
36 kW
|
40 kW
|
50 kW
|
60 kW
|
75 kW
|
60 kW
|
75 kW
|
|
|
AC Nennspannungsbereich
|
|
176~264 V
|
176~264 V
|
176~264 V
|
176~264 V
|
176~264 V
|
176~264 V
|
176~264 V
|
176~264 V
|
176~264 V
|
176~264 V
|
176~264 V
|
|
|
Max. Wechselspannung
|
|
220 V
|
220 V
|
220 V
|
220 V
|
220 V
|
220 V
|
220 V
|
220 V
|
220 V
|
220 V
|
220 V
|
|
|
Max. Ausgangsstrom
|
|
103,9 A
|
115,5 A
|
144,3 A
|
173,2 A
|
103,9 A
|
15,5 A
|
144,3 A
|
173,2 A
|
196,8 A
|
173,2 A
|
196,8 A
|
|
|
Max. Wechselstrom
|
|
94,5 A
|
105 A
|
131,2 A
|
157,5 A
|
94,5 A
|
105 A
|
131,2 A
|
157,5 A
|
196,8 A
|
157,5 A
|
196,8 A
|
|
|
Netzfrequent/ Bereich
|
|
55-65 Hz
|
55-65 Hz
|
55-65 Hz
|
55-65 Hz
|
55-65 Hz
|
55-65 Hz
|
55-65 Hz
|
55-65 Hz
|
55-65 Hz
|
55-65 Hz
|
55-65 Hz
|
|
|
Frequenz
|
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
|
|
Klirrfaktor
|
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
|
|
Anzahl der Anschlussphasen
|
|
|
Max. Wirkungsgrad
|
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
|
|
Europ. Wirkungsgrad
|
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
|
|
|
|
Abmessungen (H/B/T)
|
|
725x960x369 mm
|
725x960x369 mm
|
725x960x369 mm
|
725x960x369 mm
|
725x960x369 mm
|
725x960x369 mm
|
725x960x369 mm
|
725x960x369 mm
|
725x960x369 mm
|
725x960x369 mm
|
725x960x369 mm
|
|
|
Gewicht
|
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
|
|
Nachtverbrauch
|
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
|
|
Betriebstemperaturbereich
|
-30 ~ +60 ℃
|
|
Transformator
|
Transformatorlos
|
|
Schutzklasse
|
IP66
|
|
Feuchte
|
0-100 %
|
|
Max. Höhe
|
4000 m
|
|
Schnittstelle
|
RS 485, WLAN
|
|
Display
|
LED
|
|
|
|
Schutzeinrichtungen
|
Anti Insel-Schutz (ENS), Kurzschlussschutz, Überspannungsschutz, Überstromschutz, Übertemperatursicherung, Fehlerstrom-Schutzeinrichtung, Verpolungsschutz, Erdschlussüberwachung, Isolationsüberwachung, Netzüberwachung
|