Modellnummer
|
|
GT3-75K-12
|
GT3-75K-11
|
GT3-100K-12
|
GT3-110K-12
|
GT3-75K-1
|
GT3-100K-11
|
GT3-110K-11
|
GT3-125K-11
|
GT3-100K-1
|
GT3-110K-1
|
GT3-125K-1
|
|
|
|
|
Max. DC-Leistung
|
|
112,5 kW
|
112,5 kW
|
150 kW
|
165 kW
|
112,5 kW
|
150 kW
|
165 kW
|
187,5 kW
|
150 kW
|
165 kW
|
187,5 kW
|
|
|
Max. Eingangsspannung
|
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
|
|
Nominal Eingangsspannung
|
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
600 V
|
|
|
Min. Eingangsspannung
|
|
200 V
|
200 V
|
200 V
|
200 V
|
200 V
|
200 V
|
200 V
|
200 V
|
200 V
|
200 V
|
200 V
|
|
|
Max. Einggangsstrom
|
|
160 A
|
240 A
|
240 A
|
240 A
|
320 A
|
320 A
|
320 A
|
320 A
|
400 A
|
400 A
|
400 A
|
|
|
MPP(T) Spannungsbereich
|
|
180~1000 V
|
180~1000 V
|
180~1000 V
|
180~1000 V
|
180~1000 V
|
180~1000 V
|
180~1000 V
|
180~1000 V
|
180~1000 V
|
180~1000 V
|
180~1000 V
|
|
|
Anzahl MPP Tracker
|
|
|
DC Eingänge
|
|
8
|
12
|
12
|
12
|
16
|
16
|
16
|
16
|
20
|
20
|
20
|
|
|
|
|
Nominal AC-Leistung
|
|
75 kW
|
75 kW
|
100 kW
|
110 kW
|
75 kW
|
100 kW
|
110 kW
|
125 kW
|
100 kW
|
110 kW
|
125 kW
|
|
|
AC Nennspannungsbereich
|
|
320~480 V
|
320~480 V
|
320~480 V
|
320~480 V
|
320~480 V
|
320~480 V
|
320~480 V
|
320~480 V
|
320~480 V
|
320~480 V
|
320~480 V
|
|
|
Max. Ausgangsstrom
|
|
114 A
|
114 A
|
167,1 A
|
183,8 A
|
114 A
|
167,1 A
|
183,8 A
|
208,9 A
|
167,1 A
|
183,8 A
|
208,9 A
|
|
|
Max. Wechselstrom
|
|
114 A
|
114 A
|
151,9 A
|
167,1 A
|
114 A
|
151,9 A
|
167,1 A
|
189,9 A
|
151,9 A
|
167,1 A
|
189,9 A
|
|
|
Netzfrequent/ Bereich
|
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
|
|
Frequenz
|
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
|
|
Klirrfaktor
|
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
|
|
Anzahl der Anschlussphasen
|
|
|
Max. Wirkungsgrad
|
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
98,5 %
|
|
|
Europ. Wirkungsgrad
|
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
|
|
|
|
Abmessungen (H/B/T)
|
|
960x725x369 mm
|
960x725x369 mm
|
960x725x369 mm
|
960x725x369 mm
|
960x725x369 mm
|
960x725x369 mm
|
960x725x369 mm
|
960x725x369 mm
|
960x725x369 mm
|
960x725x369 mm
|
960x725x369 mm
|
|
|
Gewicht
|
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
87 kg
|
|
|
Nachtverbrauch
|
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
< 5 W
|
|
|
Betriebstemperaturbereich
|
-30 ~ +60 ℃
|
|
Transformator
|
Transformatorlos
|
|
Schutzklasse
|
IP66
|
|
Feuchte
|
0-100 %
|
|
Max. Höhe
|
4000 m
|
|
Schnittstelle
|
RS 485, WLAN
|
|
Display
|
LED
|
|
|
|
Schutzeinrichtungen
|
Anti Insel-Schutz (ENS), Kurzschlussschutz, Überspannungsschutz, Überstromschutz, Fehlerstrom-Schutzeinrichtung, Verpolungsschutz, Erdschlussüberwachung, Isolationsüberwachung, Netzüberwachung
|
|
|
|
PDF des Herstellers herunterladen
|
|