Modellnummer
|
|
ROSA A2-3K-3P
|
ROSA A2-4K-3P
|
ROSA A2-5K-3P
|
ROSA A2-6K-3P
|
ROSA A2-8K-3P
|
ROSA A2-10K-3P
|
ROSA A2-12K-3P
|
ROSA A2-15K-3P
|
ROSA A2-17K-3P
|
ROSA A2-20K-3P
|
ROSA A2-25K-3P
|
ROSA A2-30K-3P
|
|
|
|
|
Max. DC-Leistung
|
|
5 kW
|
6 kW
|
7,5 kW
|
9 kW
|
12 kW
|
15 kW
|
18 kW
|
22,5 kW
|
25,5 kW
|
30 kW
|
37,5 kW
|
45 kW
|
|
|
Max. Eingangsspannung
|
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
1000 V
|
|
|
Max. Gleichspannung
|
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
|
|
Min. Eingangsspannung
|
|
160 V
|
160 V
|
160 V
|
160 V
|
160 V
|
160 V
|
160 V
|
160 V
|
160 V
|
160 V
|
160 V
|
160 V
|
|
|
Max. Einggangsstrom
|
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
40 A
|
52 A
|
64 A
|
64 A
|
80 A
|
80 A
|
|
|
MPP(T) Spannungsbereich
|
|
150~850 V
|
150~850 V
|
150~850 V
|
150~850 V
|
150~850 V
|
150~850 V
|
150~850 V
|
150~850 V
|
150~850 V
|
150~850 V
|
150~850 V
|
150~850 V
|
|
|
Anzahl MPP Tracker
|
|
|
DC Eingänge
|
|
|
|
|
Nominal AC-Leistung
|
|
3 kW
|
4 kW
|
5 kW
|
6 kW
|
8 kW
|
10 kW
|
12 kW
|
15 kW
|
17 kW
|
20 kW
|
25 kW
|
30 kW
|
|
|
Nominal Ausgangsspannung
|
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
|
|
Max. Ausgangsstrom
|
|
5,3 A
|
7 A
|
8,5 A
|
10,5 A
|
13,5 A
|
17 A
|
21,5 A
|
27 A
|
30 A
|
32 A
|
40 A
|
48 A
|
|
|
Frequenz
|
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50 Hz
|
|
|
Leistungsfaktor (cosφ)
|
|
|
Klirrfaktor
|
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
|
|
Anzahl der Anschlussphasen
|
|
3
|
3
|
3
|
3
|
3
|
3
|
3
|
3
|
3
|
3
|
3
|
1, 3
|
|
|
Max. Wirkungsgrad
|
|
98 %
|
98 %
|
98 %
|
98 %
|
98,2 %
|
98,2 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,5 %
|
98,5 %
|
|
|
Europ. Wirkungsgrad
|
|
97,5 %
|
97,5 %
|
97,5 %
|
97,5 %
|
97,5 %
|
97,5 %
|
97,5 %
|
97,5 %
|
97,8 %
|
97,8 %
|
98 %
|
98,1 %
|
|
|
|
|
Abmessungen (H/B/T)
|
|
588x426x250 mm
|
588x426x250 mm
|
588x426x250 mm
|
588x426x250 mm
|
588x426x250 mm
|
588x426x250 mm
|
588x426x250 mm
|
588x426x250 mm
|
588x426x250 mm
|
588x426x250 mm
|
588x426x250 mm
|
588x426x250 mm
|
|
|
Gewicht
|
|
20 kg
|
20 kg
|
20 kg
|
20 kg
|
22 kg
|
22 kg
|
22 kg
|
28 kg
|
28 kg
|
28 kg
|
35 kg
|
35 kg
|
|
|
Geräusch
|
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 40 dB(A)
|
< 40 dB(A)
|
< 40 dB(A)
|
< 40 dB(A)
|
< 40 dB(A)
|
|
|
Betriebstemperaturbereich
|
-25 ~ +60 ℃
|
|
Transformator
|
Transformatorlos
|
|
Feuchte
|
0-100 %
|
|
Kühlung
|
Lüfter
|
|
Max. Höhe
|
4000 m
|
|
Schnittstelle
|
RS 485, WLAN, CAN, GPRS, 4G
|
|
Display
|
LCD, LED
|
|
|
|
Schutzeinrichtungen
|
Anti Insel-Schutz (ENS), Kurzschlussschutz, Überspannungsschutz, Überstromschutz, Verpolungsschutz, Erdschlussüberwachung, Isolationsüberwachung, Netzüberwachung
|