Modelnummer
|
BNT003KTL
|
BNT004KTL
|
BNT005KTL
|
BNT006KTL
|
BNT008KTL
|
BNT010KTL
|
BNT012KTL
|
BNT013KTL
|
BNT015KTL
|
BNT017KTL
|
BNT020KTL
|
BNT025KTL
|
|
Eingang (DC)
|
|
Max. DC-Leistung
|
5,1 kW
|
6 kW
|
7,5 kW
|
9 kW
|
12 kW
|
15 kW
|
18 kW
|
19,5 kW
|
22,5 kW
|
25,5 kW
|
30 kW
|
37,5 kW
|
|
Max. Eingangsspannung
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
1100 V
|
|
Max. Gleichspannung
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
620 V
|
|
Min. Eingangsspannung
|
150 V
|
150 V
|
150 V
|
150 V
|
150 V
|
150 V
|
150 V
|
150 V
|
150 V
|
150 V
|
150 V
|
150 V
|
|
Max. Einggangsstrom
|
30 A
|
30 A
|
30 A
|
30 A
|
30 A
|
30 A
|
30 A
|
30 A
|
52 A
|
64 A
|
64 A
|
64 A
|
|
MPP(T) Spannungsbereich
|
150~1000 V
|
150~1000 V
|
150~1000 V
|
150~1000 V
|
150~1000 V
|
150~1000 V
|
150~1000 V
|
150~1000 V
|
150~1000 V
|
150~1000 V
|
150~1000 V
|
150~1000 V
|
|
Anzahl MPP Tracker
|
|
DC Eingänge
|
|
Steckverbinder
|
MC4
|
MC4
|
MC4
|
MC4
|
MC4
|
MC4
|
MC4
|
MC4
|
MC4
|
MC4
|
MC4
|
MC4
|
|
Ausgang (AC)
|
|
Max. AC-Leistung
|
3,3 kW
|
4,4 kW
|
5,5 kW
|
6,6 kW
|
8,8 kW
|
11 kW
|
13,2 kW
|
14,3 kW
|
16,5 kW
|
18,7 kW
|
22 kW
|
27,5 kW
|
|
Nominal AC-Leistung
|
3 kW
|
4 kW
|
5 kW
|
6 kW
|
8 kW
|
10 kW
|
12 kW
|
13 kW
|
15 kW
|
17 kW
|
20 kW
|
25 kW
|
|
Nominal Ausgangsspannung
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
230, 400 V
|
|
Max. Ausgangsstrom
|
5,3 A
|
7 A
|
8,5 A
|
10,5 A
|
13,5 A
|
17 A
|
21,5 A
|
22 A
|
27 A
|
30 A
|
32 A
|
40 A
|
|
Netzfrequent/ Bereich
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
45-65 Hz
|
|
Frequenz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
50, 60 Hz
|
|
Leistungsfaktor (cosφ)
|
|
Klirrfaktor
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
< 3 %
|
|
Anzahl der Anschlussphasen
|
|
Max. Wirkungsgrad
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,3 %
|
98,7 %
|
98,7 %
|
98,7 %
|
98,7 %
|
98,75 %
|
98,75 %
|
98,75 %
|
|
Europ. Wirkungsgrad
|
97,61 %
|
97,95 %
|
98 %
|
98,05 %
|
98,05 %
|
98,23 %
|
98,23 %
|
98,23 %
|
98,23 %
|
98,35 %
|
98,35 %
|
98,35 %
|
|
Allgemeine Daten
|
|
Abmessungen (H/B/T)
|
510x370x167 mm
|
510x370x167 mm
|
510x370x167 mm
|
510x370x167 mm
|
510x370x192 mm
|
510x370x192 mm
|
510x370x192 mm
|
510x370x192 mm
|
510x370x192 mm
|
535x370x197 mm
|
535x370x192 mm
|
535x370x192 mm
|
|
Gewicht
|
16 kg
|
16 kg
|
16 kg
|
16 kg
|
15 kg
|
15 kg
|
15 kg
|
17 kg
|
17 kg
|
19 kg
|
19 kg
|
19 kg
|
|
Nachtverbrauch
|
< 1 W
|
< 1 W
|
< 1 W
|
< 1 W
|
< 1 W
|
< 1 W
|
< 1 W
|
< 1 W
|
< 1 W
|
< 1 W
|
< 1 W
|
< 1 W
|
|
Geräusch
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 30 dB(A)
|
< 40 dB(A)
|
< 40 dB(A)
|
< 40 dB(A)
|
< 40 dB(A)
|
< 40 dB(A)
|
< 51 dB(A)
|
|
Betriebstemperaturbereich
|
-25 ~ +60 ℃
|
Transformator
|
Transformatorlos
|
Schutzklasse
|
IP65
|
Feuchte
|
0-100 %
|
Kühlung
|
Natürliche Konvektion, Lüfter
|
Max. Höhe
|
4000 m
|
Schnittstelle
|
RS 485, WLAN
|
Schutzeinrichtungen
|
|
Schutzeinrichtungen
|
Anti Insel-Schutz (ENS), Kurzschlussschutz, Überspannungsschutz, Überstromschutz, Übertemperatursicherung, Fehlerstrom-Schutzeinrichtung, Verpolungsschutz
|
PDF
|
|
PDF Datei des Unternehmens Herunterladen
|
|